大约有 40,000 项符合查询结果(耗时:0.0318秒) [XML]
Generating a random & unique 8 character string using MySQL
I'm working on a game which involves vehicles at some point. I have a MySQL table named "vehicles" containing the data about the vehicles, including the column "plate" which stores the License Plates for the vehicles.
...
How to fix: “UnicodeDecodeError: 'ascii' codec can't decode byte”
...quire a little configuration. Always use Unicode strings for SQL queries.
MySQL
In the connection string add:
charset='utf8',
use_unicode=True
E.g.
>>> db = MySQLdb.connect(host="localhost", user='root', passwd='passwd', db='sandbox', use_unicode=True, charset="utf8")
PostgreSQL
Ad...
add column to mysql table if it does not exist
...
Note that INFORMATION_SCHEMA isn't supported in MySQL prior to 5.0. Nor are stored procedures supported prior to 5.0, so if you need to support MySQL 4.1, this solution isn't good.
One solution used by frameworks that use database migrations is to record in your database...
`Apache` `localhost/~username/` not working
... finish worked for me: https://www.computersnyou.com/3376/setup-apache-php-mysql-macosx-10-10-yosemite/
Basic instructions added in response to suggestion from rozkosz:
These instructions are for setting up apache from scratch after upgrading the Yosemite. It seems like you've done most of this...
如何在Visual Studio中运行和调试汇编代码 - 更多技术 - 清泛网 - 专注C/C++及内核技术
如何在Visual Studio中运行和调试汇编代码使用内联汇编__asm,如下:int _tmain(int argc, _TCHAR* argv[]){ int a = 1; __asm{ ...使用内联汇编__asm,如下:
int _tmain(int argc, _TCHAR* argv[])
{
int a = 1;
__asm{
x...
How to drop unique in MySQL?
...
Simply you can use the following SQL Script to delete the index in MySQL:
alter table fuinfo drop index email;
share
|
improve this answer
|
follow
...
如何获取IE (控件)的所有链接(包括Frameset, iframe) - 其他 - 清泛IT社...
来源:新浪博客
IE 顶层 body 节点通过IHTMLElement->get_all 方法无法获取iframe 里面的节点列表:
CComPtr<IHTMLElement> body;
...
CComPtr<IDispatch> spDispCollection;
body->get_all(&spDispCollection);复制代码所以要获取iframe/frame(frameset) ...
如何实现phpcms和discuz的Cookie同步 - 更多技术 - 清泛网 - 专注C/C++及内核技术
如何实现phpcms和discuz的Cookie同步===本文导读===UCenter实现各系统通信的原理如何实现phpcms和discuz的Cookie同步===全文阅读===整合phpcms v9和discuz X3 2实现同步登陆 ===本文导读===
UCenter实现各系统通信的原理
整合phpcms v9和discuz X3.2实...
Modbus硬件控制02——modbus继电器 - 创客硬件开发 - 清泛IT社区,为创新赋能!
...置均通过485通信口进行设置,且可通过产品上的按键进行重置为默认设置,即为9600波特率,8个数据位,偶校验,1个停止位。
二、模块功能
本模块具备一路数字输入和一路数字输出,还具备一个标准的 RS-485 通讯接口,通信...
How to truncate a foreign key constrained table?
...
As per mysql documentation, TRUNCATE cannot be used on tables with foreign key relationships. There is no complete alternative AFAIK.
Dropping the contraint still does not invoke the ON DELETE and ON UPDATE.
The only solution I can...
